Part setup for Dentistry

Composer 2.0 automatically detects appliance type (for some industries) and then automatically orients and support the part for optimum printing outcomes.

Below is a guide to help optimise print accuracy and accuracy for a range of dental appliances.

Dental models

Part Orientation

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Indication listRecommended Layer ThicknessRecommended Part Orientation
Crown and Bridge Models50 µmHorizontal
Dental Implant models50 µmHorizontal
RPD and Denture Models50 µmHorizontal
Diagnostic Wax-up Models100 µmHorizontal/Vertical
Study models100 µmHorizontal/Vertical
Dental Thermoforming models100-150 µmHorizontal/Vertical

Horizontal

  • Crown and Bridge Models
  • Dental Implant Models
  • RPD and Denture Models
dentamodel-horizontal

Vertical

  • Study Models
  • Diagnostic Wax-up Models
  • Dental Thermoforming Models
dentamodel-vertical

Hollowing models

  • Make sure hollow models have drain holes at the base of the models to prevent volumetric pressures from occuring.  This creates a phenominom we call ‘Suction Cup’. Learn more here >
  • Hollow models can still carry a lot of liquid resin in their cavities after printing. Especially with higher viscous materials. This can lead to increased cleaning efforts and quicker contamination of your cleaning solution.
    Consider printing solid models over hollow models for process optimisation.

Asiga dental model materials

Dentamodel-1000-1334

DentaMODEL

The gold standard in dental model materials.  Exceptional accuracy, surface finish and colour.
Trusted globally. 

Explore DentaMODEL >

Dentastudy-1000-1334

DentaSTUDY

Denta is a high heat resistant material with unique ‘Anti-Stick’ surface release chemistry making it perfect for vacuum and pressure thermoforming.

Explore DentaSTUDY >

Dentaform-1000-1334

DentaFORM Grey

Asiga DentaFORM is a high heat resistant material with unique ‘Anti-Stick’ surface release chemistry making it perfect for vacuum and pressure thermoforming.

Explore DentaFORM >

Dentaform-beige-1000-1334

DentaFORM Beige

Asiga DentaFORM Beige is a high heat resistant material with unique ‘Anti-Stick’ surface release chemistry making it perfect for vacuum and pressure thermoforming.

Explore DentaFORM >

 

Oclussal Splints / Night Guards

Part Orientation

For orientation of splints please refer to the guidelines of the material manufacturer.  As a general guide it is typically best to orient the splint with the posterior closest to the platform standing vertically or angled between 5-30 degrees from vertical.

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

UltraGLOSS

Print splints with a glossy surface finish direct from the 3D printer with UltraGLOSS.

Learn more >

Denture Bases

Part Orientation

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Indication listRecommended Slice ThicknessRecommended part orientation
Denture Base 50-100 µm
50 µm for higher quality surface
100 µm for quicker print speed
60-80 Degree inclination with the intaglio surface towards the build platform.
Upper Dentures should be oriented so that the posterior region is closest to the build platform.
Lower Dentures should be oriented so that the anterior region is closest to the build platform.
dentabase

Design tips

  • A 50-100 µm spacing between the denture base & tooth is recommended for best fitment.
  • Some material manufacturers recommend adding a minimum of one structural bar to bridge between the two sides of the arch.  This can in some cases prevent warping which can be more prominent for lower dentures.

Asiga denture base material

Dentabase-1000-1334

DentaBASE

High strength and rigidity, ease of finishing and excellent adhesion characteristics for bonding.

Explore DentaBASE >

Denture teeth

Part Orientation

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Indication listRecommended Slice ThicknessRecommended part orientation
Denture Base 50-100 µm
50 µm for higher quality surface
100 µm for quicker print speed
60-80 Degree inclination with the intaglio surface towards the build platform.
Upper Dentures should be oriented so that the posterior region is closest to the build platform.
Lower Dentures should be oriented so that the anterior region is closest to the build platform.
dentatooth

Design tips

  • A 50-100 µm spacing between the denture base & tooth is recommended for best fitment.

Asiga denture teeth material

Dentatooth-1000-1334

DentaTOOTH

High strength, high-wear and stain resistant 3D printable resin for the production of Denture Teeth and Temporary Dental Restorations.

Available in a range of Vita Colour shades including A1, A2, A3, B1, B2, B3.

Explore DentaTOOTH >

All-on-X

Part Orientation

To achieve optimum accuracy and surface finish we recommend orienting AOX cases flat (horizontal to build platform).

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Custom Trays

Part Orientation

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Indication listRecommended slice thicknessRecommended part orientation
Custom Impression Trays100-150 µm.Custom Impression Trays should be oriented so that the intaglio surface of the tray is facing away from the build platform. Angulation of the custom tray is not crucial.
dentatray

Asiga custom tray material

Dentatray-turqoise-1000-1334

DentaTRAY Turquoise

High strength, high-wear and stain resistant 3D printable resin for the production of Denture Teeth and Temporary Dental Restorations.

Explore DentaTRAY >

Dentatray-orange-1000-1334

DentaTRAY Orange

High strength, high-wear and stain resistant 3D printable resin for the production of Denture Teeth and Temporary Dental Restorations.

Explore DentaTRAY >

Surgical Guides

Part Orientation

dentaguide

To achieve an optimum fit with an implant sleeve we recommend orienting the guide so that the sleeve sits perpendicular to the build platform.

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Indication listRecommended Layer ThicknessRecommended Part Orientation
Implant Surgical Guides100 µmSee below
Gingivectomy Surgical Guides100 µmSee below
Bone Reduction Guides100 µmSee below
Implant Abutment Positioning Guides100 µmSee below

Asiga surgical guide material

Dentaguide-1000-1334

DentaGUIDE

Rigid, clear, autoclavable, biocompatible material engineered for the fabrication of surgical guides.

Explore DentaGUIDE >

Try-in Denture

Part Orientation

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

dentatry
Indication listRecommended layer thicknessRecommended part orientation
Try-in Dentures100 µm60-80 Degree Inclination with the intaglio surface facing towards the build platform.
Upper Try-in Dentures should be oriented so that the posterior region is closest to the build platform.
Lower Try-in Dentures should be oriented so that the anterior region is closest to the build platform.

Asiga tray-in denture material

Dentatry-1000-1334

DentaTRY

DentaTRY is easy to carve, adjust, and add wax to make the required adjustments in the Try-In phase.

Available in a range of Vita Colour shades including A1, A2, A3, B1, B2, B3.

Explore DentaTRY >

Indirect Bonding Trays

dentaibt

Part Orientation

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Indication listRecommended layer thicknessRecommended part orientation
Indirect Bonding Trays100 µmHorizontal: Indirect bonding trays should be oriented so that they are horizontal touching the build platform on a flat plain.

Asiga IBT material

Dentaibt-1000-1334

DentaIBT

DentaIBT is a clear and flexible material used to aid the accurate positioning of orthodontic brackets onto the patient’s teeth.

Explore DentaIBT >

Gingiva

dentagum

Part Orientation

Part orientation can be a major contributor to the output quality and accuracy of the object being printed. 

Indication listRecommended slice thicknessRecommended part orientation
Gingiva Mask100-150 µmHorizontal: Gingiva Masks should be oriented so that they are horizontal touching the build platform on a flat plain.

Asiga gingiva material

Dentagum-1000-1334

DentaGUM

A flexible pink material developed to replicate the patient’s gingiva and an essential component when producing a dental implant case.

Explore DentaGUM >